Friday, 30 December 2016

Lucky Enough today Again to get a Job at one of my Customers Places!
So up dates on #aqueousecosolar Reading

Highland Park QLD 4211

5Kw System
20 Panels x 250watts = 5KW

3years
Energy Australia
FIT = $0.06
First Clean - Clean & Treatment $250 - PAID

07/11/2016
READING - 15636 Kwh
Check up While onsite

31/12/16 - 54 Days
READING - 16900 Kwh = 23.407407 Kwh/Day
 - Inverter Showed 29.9 Kwh for Yesterday :)

Proof again!!!!




Wednesday, 14 December 2016

#aqueous shows performance again!


12 Months from First Clean and Treatment

Mudgeeraba QLD - Barter Card Customer

4.6KW System - 3 years old

First Clean- Eco Solar Program

05/12/15
Reading - 19522Kwh (Average of 17.83Kwh/Day Over 3 years) Aiming for 19.32Kwh/Day

12 Month Check up

15/12/16 - 375 Days
Reading - 27145 Kwh = 20.328 Kwh/Day - Above what I was Aiming For :)
P.V Watts = 6783 Kwh/year = 18.583561 Kwh/Day!
CEC Average = 19.32 Kwh/Day!

Tuesday, 6 December 2016

Simple



https://www.youtube.com/watch?v=JjainfcrBWg


Monday, 28 November 2016

#aqueous Customer Results After 12 Months

Hope Island, Gold Coast QLD

Greg - Called 06/11/15 - 5KW System - 24 Panels x $25 = $600 (covers 3 years)
Product is Warrantied for 2 Years, So I re Apply Every 2nd Year!


Currently Getting Approx 3000w Max Reading off inverter = 40% Loss

First Clean - Alpha Eco Solar - Summers coming Special
25/11/15 - Confirmed - $600 Paid 27/11/15
Reading - 13262.1Kwh - Looking at about 16.97wh/Day ( aim for 21Kwh/Day)

12 Month Inspection
29/11/16
Reading - 20825.7 Kwh = 20.609 Kwh/Day over the last 367 Days

Wednesday, 16 November 2016

Results From Todays Clean 17/11/16

Tallai QLD 4213
8 Panels + 2 HWS -3 Yrs Old System - 2Kw System

First Clean 10/11/14
Reading - 6639Kwh -
Solar Highline 07/13 - Due for Service 07/17!! - $450

Second Clean 18/11/15 - (372 Days)
Reading - 8504Kwh = 5.0134 Kwh/Day

Intermittent Reading
20/02/16 - (464)
Reading - 9082Kwh - 5.265 Kwh/Day

12 monthly check up
17/11/16
Reading - 10480 Kwh
(736) Days from First Clean - 5.21875 Kwh/Day
(364) Days from Last Clean - 5.42857 Kwh/Day

Monday, 7 November 2016

Latest Results


15 Kw System
BURLEIGH HEADS


FIRST CLEAN & TREAT
06/05/16
READING - 40169KWH

09/05/16
READING - 40316KWH = 73.5KWH/DAY OVER LAST 24 HRS
CEC Average = 63 Kwh/Day

22/09/16 - 133 Days
Reading - 49501 Kwh = 69.06 Kwh/Day
CEC Average = 63 Kwh/Day

06/11/16 - 182.5 Days
6 MONTH CHECK UP
READING - 53681kwh = 74.038 Kwh/Day

Friday, 4 November 2016

More results

Bethania QLD 4205

Estimated Installed 2011?

Solar Clean - 2 Kw Inverter - 6 x 250w Panels = 1.5 Kw
New Inverter 20/01/14
CEC Average = 6.3Kwh/Day

First Clean
15/01/16
Reading - 4438kwh on Inverter ( 725 Days for calculation) - 6.12Kwh/Day

12 Month Inspection
03/11/16 - 288 Days
Reading - 6225 Kwh = 6.20486 Kwh/Day
P.V Watts Calculator = 1892 Kwh/Year = 5.18356 Kwh/Day




1.5kw System, Installed 2011
6  Panels,
Bethania QLD 4205

CEC Average = 6.3 Kwh/Day

New Inverter Installed 22nd Dec 2015

First Clean
15/01/16
Reading - 161 (17 Days) - 9.47Kwh/Day - Limited time frame for accurate reading!

12 Month Check Up
03/11/16 - 288 Days
Reading - 1863 Kwh = 5.9097 Kwh/Day
P.V Watts Calculator = 2139 Kwh/Yr = 5.86 Kwh/Day


Another Update of Results


Solar Clean - 5 Kw System
Paradise Point QLD 4216

Age Estimated at 3 years 50 Days (Dated at 15/04/16)
22 Panels x 230 Watts = 5.060 KW

First Clean 02/11/15 - Yes - Unsure how old system would be as just bought place
Reading - 26232.08Kwh

08/10/15
Reading - 25580.4Kwh

First Clean 02/11/15 - 24 Days - Yes
Reading - 26232.08Kwh - 27.15Kwh/Day

21/01/16 - 79 Days
Reading - 28338.86Kwh - 26.67Kwh/Day

15/04/16 - 84 Days
Reading - 30572.45Kwh - 26.59Kwh/Day
187 Days = 30572.45 - 25580.4 / 187 = 26.695 Kwh/Day This is 27% Better than average!
Going Great Gary.

03/05/16 - 205 Days from clean
Reading = 30999.11Kwh
30999.11 - 25580.4 / 205 = 5418.71 Kwh / 205 = 26.4327 Kwh/Day - Still Great!

06/10/16 - 339 Days from First Reading
Reading - 34336.16Kwh = 8755.76 Kwh / 339 = 25.828 Kwh/Day
22.99% Better than CEC Average of 21 KWH / Day

02/11/16 - 365 Days From First Reading 02/11/15
$250 - For Treatment & Clean
READING - 35088.34 Kwh = 24.26 Kwh/Day

15.54% Better than CEC Average of 21 Kwh/Day
Pv Watts Calculator for Age of System = 7221 Kwh/Last 12 Mth = 19.783561 Kwh/Day
Need to Clean out Gutter While Onsite - Done

Monday, 31 October 2016

Comparing Pricing that I have seen out there at the moment


Special $95 up to 5 Kw System
Points to take into account
- De-Ionised Water Clean
- Needs to be done every 6 Months to gain a cost effective result for you!
- over a 3 year time equals 7 times
- cost equals $665 total over this time

Special up to 12 Panels Clean for Just $99
Points
- De-Ionised Water Clean
- Needs to be done every 6 Months to gain a cost effective result for you!
- over a 3 year time equals 7 times
- cost equals $665 total over this time
- for 12 Panels cost equals $18.47 Per Panel, Per Year!

Price Starts From $110 + Gst
Points
- De-Ionised Water Clean
- Needs to be done every 6 Months to gain a cost effective result for you!
- over a 3 year time equals 7 times
- cost equals minimum $770 + GST
- For 8 Panels cost equals $32.08 Per Panel, Per Year!

MY PRICING
STARTS AT $100
1.5KW SYSTEM $100/YEAR = $300 OVER 3 YEARS
8 Panels = $12.50 Per Panel, Per Year

2KW SYSTEM $100/YEAR
3KW SYSTEM $150/YEAR
4KW SYSTEM $200/YEAR
5KW SYSTEM $250/YEAR
24 Panels = $10.42 Per Panel, Per Year!


Claims :)
Your Panels Lose 25 - 40% per Year is what I have seen on the Web.

If this is Fact. for $665 you would need to be GAINING an Minimum of $1330 savings on your Power bills from your Solar to be beneficial.

Over the Last 6 years of Gathering Information on the Lose of Systems of my customers then most common lose is 20-25% if never Cleaned from Day one.

The Average Gain I get my Customers over the First 12 Months of my Cleaning Program is 20-25%

IF YOU WOULD LIKE TO BOOK IN A FREE NO OBLIGATION CHECK OF YOUR SYSTEMS PRODUCTION, CALL AND BOOK IN Scott Meloni 0402940716

Wednesday, 26 October 2016

Latest Results Update

Nerang - Media Solutions

- 5Kw System
NORTH
27 Panels x 190watt = 5.130 Kw of Panels
CEC Average =  21Kwh/Day

First clean - Deionised Water
22/04/14
Reading - 14576Kwh = 20.23Kwh/Day

Second clean - 181.5 Days - Deionised Water
21/10/14
Reading - 18231Kwh = 20.1377 Kwh / Day

Third Clean - Alpha Eco Solar - 199.5 Days
08/05/15
Reading - 22888Kwh = 23.3434 Kwh / Day

06/11/15 - 180 Days
Reading - 26547Kwh - 20.27 Kwh/ Day

06/05/16 - 182 Days
Reading - 30807 Kwh? see if i am close?

09/05/16 - 185 Days - Aqueous Treatment
Reading - 30894 Kwh = 23.5 Kwh/Day

29/09/16 - Reading As onsite - 319 Days
Reading - 33457 Kwh = 21.66 Kwh/Day

26/10/16 - 167 Days from 09/05/16 (916.5 Days from First Clean)
Estimated Reading - 34024 Kwh 26/10/16 - 4.46am Calculated Estimate, see how I go?
Reading - 34158Kwh = 21.56Kwh/Day based from first clean readings

P.V Watts Calculator = 7091 Kwh/Year (Reading Estimated 33638 Kwh 26/10/16)
5.5 Years of System running at 21 Kwh/Day if Cleaned from Day One = 42157 Kwh

Gain from Cleaning Program over Last 2.5 Years =  1854.5 Kwh - 10.46% - $816
Lost From Not Cleaning From Day One =   7999.5 Kwh - 18.975% - $3519.78
Based on CEC of 21 Kwh/Day Average

Monday, 17 October 2016

I got an Opportunity to Do a Price Comparison with a Competitor Today

Both Systems are the Same Size
Next Door to each other
Both About the same age

Barona Point NSW

My Customer
2 Kw Inverter
1.520 Kw of Panels on Roof
Rebate of $0.20/Kwh

First Clean
20/10/14 - 3.3 Years old
Reading - 7571Kwh

Second Clean - Eco Solar
26/10/15 - 368 Days - Yes
Reading - 9874Kwh
Last 12 Months 6.258Kwh/Day

18/10/16 - 357 Days
Yes Confirmed 04/10/16 Text
Reading - 12080Kwh = 6.357Kwh/Day

Costs my customer for every $1 I give a Return of  $2 Electricity Savings/Performance

NEIGHBOUR - Opposition Cleaner

2 Kw Inverter
1.520 Kw of Panels on Roof
Rebate of $0.60/Kwh

First Clean
20/10/14
Reading -1095 Kwh

Second Clean - No - Got another Company Cleaning them
19/10/15
Reading -

18/10/16 - 728 Days Between Readings - SAE been Cleaning every 12 months
Reading - 4787 Kwh = 5.07 Kwh/Day (20% lower than my Customers Readings)

Costs to Oppositions Customer - for every $1 for Customer,
They get a Return of  Minus $2.26 Electricity Savings/Performance

Great that they are prepared to help a Business make a nice profit!

But why are they not getting anything in Return from their Solar Investment!!!!!!!

Todays Reading Update

Banora Point NSW
2kw system
8 Panels - Pensioner
- North
Sunny Roo SR2000TL
On $0.20 Rebate
8 x 190watt = 1.520 Kw of Panels
CEC Average = 6.384 Kwh/Day

First Clean
20/10/14 - 3.3 Years old
Reading - 7571Kwh

Second Clean -  Eco Solar
26/10/15 - 368 Days - Yes
Reading - 9874Kwh - Nano
Last 12 Months 6.258Kwh/Day

18/10/16 - 357 Days
Yes Confirmed 04/10/16 Text
Reading - 12080Kwh = 6.357Kwh/Day

P.V Watts Calculator =
2160 KWh over The Last 12 Months = 5.918 Kwh/Day

Put it into Monetary Terms

Customer is Getting Approx $464 per Year Savings, just calculating on Her Rebate!

If not Clean P.V Watts Calculator = $432 per Year Savings, for Age of System

If you add in the cost of savings of not having to use Power that she has to pay for during the day!

Her cost to maintain this savings = 8.6% of what she is getting back each year
She gives me $1 and I help her save $2 !!!!

I spoke to her neighbours, who I did start cleaning, but have since been using another Solar Cleaner
They are Paying
$3.75 and getting back $2 in Return?

Can you say it is worth it?

Do you want a Return on your investment or just make money for Businesses?

I want to make money, but also want you to make money on your investment!

Thursday, 13 October 2016

Latest Results 13/10/16

1.

Reedy Creek QLD
14 Panels x 215watt = 3010 Watts
2 Hot water Panels

CEC Average = 12.6 Kwh/Day

System is 3.5 Years Old as of 2014
15/10/14 -
Reading - 15479 Kwh

11/11/15 - 391 Days
Reading - 20147 Kwh = 11.9386 Kwh/Day

13/10/16 - 728 Days
Reading = 24059 Kwh = 11.7857 Kwh/Day
337 Days = 11.608 Kwh/Day

P.V Watts Calculator = 3716 Kwh/Year on age of System
Currently Doing 4237 Kwh/Year = 14 % Better Than it Should!

Value Calculations
Current Year Savings = $1864
Not Cleaned Cal = $1635
Difference = $229 better off over the past year at minimum!


2.

Reedy Creek QLD

8 Panels x 190 watt = 1520 watt
 Lowset Tiled

2 KW Inverter
CEC Average = 6.3 Kwh/Day

3.5 Years old as of 2014
15/10/14
READING - 7216 KWH

11/11/15 - 391 Days
READING - 9455 KWH = 5.726 Kwh/Day

13/10/16 - 728 Days
READING - Inverter Faulty, Not Reading - Brad BMC Checking it out

P.V Watts Calculator Estimating 1858/Year as of 2016 = 5.09Kwh/Day

As you can see, this customers Inverter was not even working, he was unaware of this!
So I have organised to get it fixed, as the Installer is not longer available!
We do not know how long it has not been working as He does not check it.

My advice would be to at least make a date each month to just have a look at your Inverter!

Wednesday, 12 October 2016

Another Update from an Existing Customer I had a visit with yesterday 12/10/16

Southport QLD
Solar - 9 Panels - More Added around Clean Date
Inverter - 3.3KW

09/02/16
T->Energy = 11230.5kWh
Age = 3.5 Years = August 2012?
Average Estimated = 8.79 Kwh/Day
CEC Average = 13.86 Kwh/Day

30/05/16 - 111 Days from first reading
Aqueous Eco Solar Clean & Treatment
Reading - 12354.1 Kwh = 10.1225 Kwh/Day

Check Up & Reading
12/10/16 - 243 Days From First Reading = 11.3868 Kwh/Day
Reading - 13997.5 Kwh
- 122 Days From Clean & Treatment Date = 13.47 Kwh/Day

Summarised

09/02/16 Generating Estimated 8.79 Kwh/Day

30/05/16 Generating Estimated 10.1225 Kwh/Day - Cleaned and Treated, Extra Panels Added

12/10/16 Generating Estimated 13.47 Kwh/Day

Below is a Photo of Inverter Reading on 12/10/16 at 3.32pm of the Daily Generated!



Thursday, 6 October 2016

Check up of one of my First Systems Panels to Be Treated

Not showing the Best performance, still better than it should, but not as good as I want to see!

So showing my commitment to this customer, I have offered this years Clean & Treatment FREE

Hope Island QLD
5Kw System
20 x 250 watt panels
Installed Approx 2012

09/09/15 - 18610.6Kwh

29/10/15 = 50 Days
Reading - 19766.6Kwh Total
DAILY -> Energy = 23.114Kwh

14/11/15 = Inverter Readings
Reading - 20125KWH TOTAL
DAILY -> Energy = 24621 Watt (24.621Kwh)

12 Month Check up Solar
06/10/16 - Yes
- 392 Days from First Reading =
Reading - 26679.4 Kwh (20.58 Kwh/Day) - Not Bad!!

CEC Average = 21 Kwh/Day

P.V watts Calculator for Age = 7197 Kwh/Year = 19.72Kwh/Day

Tuesday, 4 October 2016

Another Annual Clean & Treatment #Aqueous Customer Results


Labrador QLD
installed 04/09/2011 - replaced inverter 2 years ago - System Facing North/North East
1.5Kw System = 6 Panels - from SunUp Solar
$0.50/Kw - Alpha Nano Clean and Application covers 3 years protection program

CEC Average = 6.3Kwh/Day

30/10/15
Reading - 6132Kwh - 5.67Kwh/Kw/Day

First Clean - Alpha Eco Solar
18/11/15
Reading - 6230Kwh - 5.44Kwh/Day

Inverter changed due to Faults

12 Month Check Up                           Energex Meter                        Bill
04/10/16 - 316 Days                           -007188                                  07/06-08/09
Reading - 1953Kwh=6.18Kwh/Day      009230  = 2042 Difference    327 Kwh

This System is getting on, or over 5 years Old!

If My Clean and Treatment Program was not Applied to this system, it would not be getting any where near these results.

Is it worth it to Keep your Panels Clean?



Wednesday, 28 September 2016

And Another Regular Customer over the last 12 months

We also helped with getting a new inverter under warranty!

Coombabah QLD 4216

Installed Feb 2011 - 1.5Kw System

First Clean - Eco Solar
02/10/15
Reading - 10419Kwh - 189.44Kwh/mth - 6.315Kwh/day (CEC  Avergae = 6.3Kwh/Day)

New Inverter Installed
Nov 2015

12 Month Check up & Clean
29/9/16 - 300 Days from new inverter install
Reading - 2285 Kwh = 7.6166 Kwh/Day


http://pvwatts.nrel.gov/pvwatts.php
Calculates at this age being 5.5 Years Old
This system should be producing 2127 Kwh/Year = 5.8274 Kwh/Day

This calculates out to being 30% better than it should be?

Is that right?

How come? :)

#aqueousecosolar !!
Another Update, As I was Called in to fix a leaking toilet.


Nerang - Media Solutions

Solarclean - 5Kw System
First clean
22/04/14
Reading - 14576Kwh - 607Kwh/Mth - 20.23Kwh/Day

Second clean - 181.5 Days
21/10/14
Reading - 18231Kwh - 20.1377 Kwh / Day

Third Clean - Alpha Eco Solar - 199.5 Days
08/05/15
Reading - 22888Kwh - 23.3434 Kwh / Day ( average = 21Kwh/Day)

06/11/15 - 180 Days
Reading - 26547Kwh - 20.27 Kwh/ Day

06/05/16 - 182 Days
Reading - 30807 Kwh? see if i am close?

09/05/16 - 185 Days
Reading - 30894 Kwh = 23.5 Kwh/Day

29/09/16 - Reading As onsite - 319 Days
Reading - 33457 Kwh = 21.66 Kwh/Day


As you can see, the Data I am collecting is showing that I am not only Keeping this customers System working to its Max, The Results are by no way dropping each year, as they should due to general Panel Age!

Thanks to Aqueous Eco Solar Treatment!

Wednesday, 21 September 2016

And Another, This time a 15 Kw Commercial System

Only 133 Days from treatment, But was going past :)

15 Kw System
BURLEIGH HEADS

SIZE:
PANELS: 100 X   WATTS
DATE INSTALLED:
CURRENT TOTAL READING:

FIRST CLEAN & TREAT
06/05/16
READING - 40169KWH

09/05/16
READING - 40316KWH = 73.5KWH/DAY OVER LAST 24 HRS
EQUALS TO 4.9KWH/KW/DAY - CEC AVERAGE = 4.2!!

22/09/16 - 133 Days
Reading - 49501 Kwh = 69.06 Kwh/Day
CEC Average = 63 Kwh/Day

Easy to see that the Average over the last 133 Days is Above the CEC Average!!!!!

9.6% Better than Average!!!
Check up of Treated System 352 Days ago, Ferry Road Southport QLD

Ferry Road, Southport QLD

20 Panels - 5 Kw System
SMA Inverter Facing North 346 Deg
First Clean - Alpha Eco Solar
05/10/15
Readings - 24604Kwh, 7.10am - 1492w, 9.05am - 3388w

Check Up
22/09/16 - 352 Days
Reading - 32953Kwh = 23.71875Kwh/Day
CEC Average = 21 Kwh/Day


As you can see Average has not dropped Below CEC Average after near on 12 months from Clean

Monday, 19 September 2016

More Proof in the Pudding

Solar Clean - Mermaid Waters, Gold Coast QLD
3 KW System $150 Clean, Treatment and Inspect
Facing - NORTH
13 x 230watt Panels = 2990 watts
Installed - April 2013?

First Clean
16/02/15
Reading - 13751 KWH

10/08/15 - 174 Days
Reading - 15779 KWH - 11.655 Kwh/Day

02/09/15 - 196 Days
Reading - 16053 KWH - 11.745 Kwh/Day

16/09/15 - 210 Days
Reading - 16228 KWH - 11.795 Kwh/Day

07/10/15 - 231 Days
Reading - 16540 KWH - 12.07 Kwh/Day


04/11/15 - 258 Days
Reading - 16951 KWH - 12.65 Kwh/Day

19/09/16 - 315 Days From 04/11/15
573 Days From 16/02/15 - 12.4886 Kwh/Day
Reading - 20907 Kwh - 12.5587 Kwh/Day
P.V Watts Calculator = 11.926 Kwh/Day


This Shows that My Clean and Treatment Program is keeping this System Producing it's Maximum for this Customer, Even though it has been so long between Clean/Check-ups, due to customer not accepting that an Annual Clean is needed.

This not only is a Great Example that the Treatment works!

But is also showing that 12 Monthly Clean and Check-ups are Equal and Less Cost to the Customer Than 6 Monthly Cleans with Standard De-Ionised Water.

Proving that my Unique Clean and Treatment is Far Superior than my Competitors!!!

Monday, 22 August 2016

Panels Facing SOUTH? What to do?

Eco Solar Treat them? Wonder if it will make a difference?



Hope Island QLD 4212
14 PV Panels = 3Kw + 2 Solar Hot Water Panels
Facing - SOUTH

20/08/2015
Reading - 16665Kwh ( Solarhart Panels and Inverter)

09/09/2015 - 20 Days
Reading = 16788Kwh
= 6.15Kwh/Day

12/01/16 (142 Days from First Records)
Reading = 18636Kwh
= 18636Kwh - 16665Kwh = 1971Kwh/142Days
= 13.880281 Kwh/Day

This is Awsome!! :)

12 month inspection - Audie Donated Books for Little Souls Childcare (5 Years of Cleans FREE)
23/08/16 (368 Days from First Reading)
Reading - 20496 Kwh
= 20496 Kwh - 16665 Kwh= 3831 Kwh / 368Days =  10.41 Kwh/Day

Better than the 6.15 Kwh / Day that we Started With?


Eco Solar Cleaned and Treated System 3 KW
Facing - "SOUTH"
10 Deg Pitch

P.V Watts Calculator for Last 12 Months = 3686 Kwh

4% Better than what they should be doing at 5 Years old and Facing SOUTH!!!

Again the Performance of Eco Solar Clean & Treatment of the Panels has shown the performance!

Thursday, 11 August 2016

Battery Back Up

I had my First Clean Customer Today, in Muwillumbah, that is still on the $0.60/Kwh FIT till the end of the Year. But has chosen to be ready for the big switch and has already installed Panels and Battery Back up Bank.


I asked him Why he chose to set it up this way?

He replied - This way they Batteries will last approx 10 years, Gel Batteries, and they cost me Approx $1500 to replace a row/bank.

This Gentleman had investigated lots of  the different systems available on the market and chose this way. So I just thought I would share it out there for those that maybe looking into Battery Back up and still are not sure if others have started to set them up.

Cheers and have a Great Weekend :)

Thursday, 28 July 2016

Well another Week goes by with a Few Of my Regular Customers. And even though we are in the colder months of the year with less production, over the last 12 Months yet again, I have achieved above average results for them.

I love making money/savings for my customers with Solar!!!! :)

Nerang QLD 4211 - 15 KW System 3.66 Years Old

25/07/2015
Reading - 21140.4Kwh + 11749.5Kwh + 25352.9Kwh
= 58242.8 (1458.3Kw per Month)
48.61Kw/Day - 3.24Kwh/KW/Day

6 Month Inspection of Panels and Alpha Clean - 27/01/16 (184.5 Days)
Reading - 25019.5Kwh + 16350.5Kwh + 30109.5Kwh
= 71479.5Kwh (71.74Kwh/Day)
P.V WATTS CALCULATOR - 16638 KWH/YR = 45.58 KWH/DAY(15Kw Systems)


12 Month Inspection of Panels and Alpha Clean
28/07/16 - 183 dAYS
Reading - 28145.5Kwh + 19845.6 Kwh + 33860.1 Kwh
= 81851.2 Kwh- 56.68 Kwh/Day

Last 12 Months Calculations
Actual Reading = 23608.4 KWH - 64.68 Kwh/Day
PVWatts Calculator = 16712 KWH - 45.786 KWh/Day

"Still produced 6896.4 Kwh more than it should have!" -  Thats over 40% better!!!



ROBINA QLD
2 KW System, Installed August 2011

Third Clean - 6 Monthly Program - $66 New price
27/01/16 ( 180 Days)
Reading - 12908kwh - 8.65 Kwh/Day

27/07/16 - (180 Days)
Reading - 14105Kwh  - 7.85 Kwh/Day

Last 12 Months
Actual Reading = 2754 Kwh - 7.545 Kwh/Day
PVWatts Calculator - 2199 Kwh - 6.025 Kwh/Day

Thats more than 25% Better than it should be producing!


Gaining and Showing you! my Customers a minimum 12 months results is the only Fair way I can find to keep you informed that what I am doing for you by Cleaning your Systems is Actually WORTH IT !!

Happy Days

Saturday, 11 June 2016

Green Electricity and Carbon Offsets

With our Election on the way, all the talk seems to be around what is our Government going to do about Alternative Energy to BROWN/COAL Energy?

My Question is WHAT ARE "YOU" Doing about it?

Do we really need a Government to do something about it?
What is we all do our little bit?

We have events like - EARTH HOUR
                                 - CLEAN UP AUSTRALIA
                                 - TREE PLANTING
                                 - RECYCLING BINS

But What is something YOU can do? The old saying I was told, just switch off!!

Do we really need all of those Appliances on? All the Time?

How green is Australia’s electricity supply?

So you already know that 14% of energy in the grid is already green. That comes from renewable generators feeding the electricity they produce into the NEM, just like traditional power plants do.3
Of this 14%, over half of it (about 60 per cent) is from hydropower plants.The Snowy Mountains Hydro-electric Scheme is Australia's largest hydro-electric generator. 
The remaining green energy in the grid comes from a combination of windbiomass and solar energies.
I Rent, so over the last two years I have been trying to come up with a way to make up like a portable Solar so I can take it with me. I am close. But this will only help me offset about 12% of our Daily Energy Use, and would have cost me About $1500, SO will take me a little over 5 Years to get my money back!
Lucky the money I have used to get the materials was mainly bartering my labour, and recycling copper, brass and cans. So really didn't cost me that money after all.
But my business is about Cleaning Solar to Help make the Most Solar Produced! from your System. So if I in return are not using as much GREEN energy as I can, to me that makes me a Hypocrite!
So I looked into switching to Green Power with Origin Energy, our Electricity Retailer.

How much does it cost?

GreenPower charges depend on your energy plan or agreement. Here’s some estimates based on an average household’s quarterly electricity bill.*
Charges effective from 14 March 2016
25% GREENPOWER50% GREENPOWER100% GREENPOWER
Charge (inc. GST)Charge (inc. GST)Charge (inc. GST)
$2 extra per week2.81c extra per kWh5.61c extra per kWh
Estimated extra costEstimated extra costEstimated extra cost
$2.00 per week or $26.00 per quarterly bill$2.70 per week or $35.13 per quarterly bill$5.39 per week or $70.13 per quarterly bill
*based on annual electricity usage of 5,000kWh and a 13 week quarterly bill.
For Predictable Plan customers, we'll fix your GreenPower charges for the 12 month period. We'll base the charges on your estimated usage over 12 months.
So to go 50% GREEN Energy it is going to cost me an EXTRA $359 per Year!! That would take up my GREEN Energy use to 62% costing me $1859 in the First Year :( I should have just bout a 2KW Solar to put on the roof of the house we rent?
It seems so expensive to help the Environment! I can see why most people do not, or can not afford to do it! 
I also found out the our household Electricity adds up to 12.01 Ton per year, to offset this at $10 per Ton = $120.10 if I was to purchase Carbon offset credits! this would work out better and cheaper! but honestly what is $120.10 going to do to help the environment from me every year?
So what I have chosen to do is SWITCH to an Electricity Retailer that is going to provide me with 50% GREEN Electricity, Guaranteed!
http://sca.viridianenergy.com.au/index.asp?CO_LA=AU_EN
And with my business of Solar Cleaning with an average of 1000 panels cleaned every year i have calculated i am also helping those with Solar produce an extra 213087 KWH per Year = 200.30178 Ton of Carbon offsetting, minimum every year. Equal to if I purchased $2003 of Carbon offsets each year!
So again WHAT ARE YOU DOING ABOUT IT?

Thursday, 2 June 2016

Energy Retailing Deregulation

So it is nearly time for SEQ to be deregulated, as of 01/07/2016

So what does this mean for you, my loyal customers?

Well here at Solarcleaner Australia I have joined up with Two Energy Retailers that are offering more for their customers. So I will be contacting you all to see if we can find time to sit down and look at your Electricity bill to see how much more I can help you save money!

So not only am I providing you with the service to Maximise your Solars performance, but am prepared to take the time to help you look into more ways to save on that ever climbing electricity bill.

One Retailer is offering an extra $0.10 FIT on top of what you are getting now!

One Retailer is offering GREEN energy at a minimum of 50% of what you pay for, for no extra cost!

One Retailer is already offering $0.11 FIT to those with Solar!

So if you get to read this, think about what you want in your Electricity, What are you interested in?
- using more GREEN energy?
- Getting extra FIT
- Getting more FIT than you currently are?



Please complete the fields below to indicate your interest in either, Cleaning and Maintenance of your Solar P.V System and/or Interest in Switching to Affordable Greener Energy for your House or Business. Do not currently have Solar on your House? Are you interested in a Quote?

NAME: ___________________________________________________________________________     

SUBURB: _________________________________________________________________________

PHONE NUMBER: ____________________________________

EMAIL: ___________________________________________________________________________

SIZE OF YOUR SYSTEM: ______________________________________________________________

APPROX AGE: ______________________________________________________________________

CURRENTLY MAINTAINED?      YES        NO

IF YES, HOW OFTEN?                 3MTHLY        6MTHLY        12MTHLY        NOT REALLY!

ARE YOU INTERESTED IN SOLAR POWER?       YES       NO

DO YOU PAY FOR GREEN ENERGY WITH YOU ELECTRICITY COMPANY?   YES   NO

ARE YOU INTERESTED IN HELPING THE WORLD THROUGH REDUCING YOUR CARBON FOOTPRINT? 

YES      NO                       

Who is your current Electricity Retailer? ______________________________                                                                                              

Wednesday, 18 May 2016

RESULTS


Nerang QLD 4211
2.8Kw System
Inverter - 2.8Kw
CEC Average = 11.76Kwh/Kw/Day
Age Estimated - April 2010 Installed?

18 Panels x $9ea = 12 Monthly
18 Panels x $6ea = 6 monthly
18 Panels x $35ea = 3 yearly with Annual Inspection
Reading 16/05/2015- 20454KW

12 Monthly Clean - Alpha Eco Solar Applied
18/05/16 - 367 Days
Reading - 23829 Kwh - 9.196185 Kwh/Day
http://pvwatts.nrel.gov/pvwatts.php = Average 8.4123285Kwh/Day
9.318% Better than it should be

Friday, 13 May 2016

Mount Nathan Winery - Clean & Treatment
System Size - 22 x 230watt Panels = 5.060 Kw
Panel Size - 230 watts
Invetre Brand - Sunteams
Inveter Size - 5 Kw
Age - Approx 5 Years
Facing - W /S-W


18/04/16
Reading - 26375 Kwh - Average Approx 14.45 Kwh / Day (Average CEC 21 Kwh / Day



13/05/16 - 25 Days
Reading - 26642kwh - 10.68 Kwh / Day

Lets get this Puppy Producing :)

Wednesday, 11 May 2016


Hi All

Results From Yesterday Mornings Clean.
This Customer Requested a Standard Clean 12 Monthly @ $9 Per Panel
I did explain that 12 Monthly Clean do not Produce much results if Any, This is Also found on my Website. So we can see That This Customers Solars Performance is Dropping Steady by around 2.2-3% each Year, Not the Estimated 15-20% loss per Year. (or should I say 35-40% That some Cleaner Claim!)
So myself here at Solar Cleaner Australia, Not Happy with these Results for my Customer, Have Decided to Put him on the Alpha Eco Solar Treatment Program. Aiming to get to at least what the CEC tell us is the Average for our Area, of 9.24Kwh/Day
Challange is "ON" :)



12 Monthly Clean Program, Standard Clean Only.
Mudgeeraba QLD
Installed Approx 2010
Size : 2.2 Kw
FIT - $0.44
Lowset Tiled Roof
12 Panels x $9 = $108 / Year
Readings
10 /05/2014 - 11429 Kw - 7.93Kwh/Day - Estimated

11/05/2015 -  14253 Kw - 7.74Kwh/Day (CEC Average = 9.24 kwh/Day for a 2.2 kW Systems)

Alpha Eco Solar Program Started!
11/05/16
Reading - 17013 kWh - 7.56 kWh/day

http://pvwatts.nrel.gov/pvwatts.php = 2391 Kwh / Year = 6.55Kwh/Day this allows age loss
We are getting at least 15.4% better than estimated amount due to age! this is good!

12 Month Check Up - Aiming for min 9.24 Kwh/Day
11/05/17

Monday, 9 May 2016

Solarclean - 5Kw System - Nerang QLD - Media Solutions
Installed April 2012

First clean - Standard De-Ionized Water
22/04/14
Reading - 14576Kwh - 20.23Kwh/Day

Second clean - 181.5 Days - Standard De-Ionized Water
21/10/14
Reading - 18231Kwh - 20.1377 Kwh / Day

Third Clean - Start Alpha Eco Solar Program - 199.5 Days
08/05/15
Reading - 22888Kwh - 23.3434 Kwh / Day ( average = 21Kwh/Day)

06/11/15 - 180.5 Days
Reading - 26547Kwh - 20.27 Kwh/ Day

09/05/16 - 182.5 Days - 12 months with Alpha Eco Solar Program
Reading - 30894 Kwh - 23.88 kWh/day


De-Ionized Water                                       Alpha Eco Solar Program            
21/10/14 - 20.1377 Kwh/Day                    06/11/15 - 20.27 Kwh/Day

08/05/15 - 23.3434 Kwh/Day                    09/05/16 - 23.88 Kwh/Day


Over the last 12 Months with the Alpha Eco Solar Program this System has produced 8006 Kwh

In Comparison to if they were not Cleaning Panels at all! 5624 Kwh per year!

42% Better - And I have been told so much over the Last 5 Years "Solar Companies Say that your Panels Don't Need Cleaning"


Thursday, 28 April 2016

NERANG QLD 4211
30 KW SYSTEM FOR A SOLAR COMPANY - ALPHA ECO SOLAR 10 KW AS A TEST
PANELS ARE ON A 2 DEG PITCH, I HAVE FOUND THIS NOT TO BE A GOOD THING!!!!


Alpha Eco Solar for 10Kw System on Roof of warehouse - 40 Panels
Coated Array - A - Looking for increase to 4.1493924kw/hr on inverter A
30/09/15 - 07:46am
Inverter A - 43066.9Kwh - 12456Hrs - (7.8Kwh - 2Hrs 55min) - 3.4575224kw/hr
Inverter B - 56389.3Kwh - 16904Hrs - (7.8Kwh - 2Hrs 51min) - 3.3358554kw/hr
Inverter C - 47703.8Kwh - 14160Hrs - (7.9Kwh - 2Hrs 50min) - 3.3689124kw/hr

30/09/15 - 10.56am
Inverter A - 43088.6Kwh - 12459Hrs - (29.5Kwh - 6Hrs 5min) - 3.4581316kw/hr
Inverter B - 56410.8Kwh - 16907Hrs - (29.3Kwh - 6Hrs 1min) - 3.3365351kw/hr
Inverter C - 47725.5Kwh - 14163Hrs - (29.6Kwh - 5Hrs 59min)-3.3697309kw/hr

28/10/15 - Check Up
Inverter A  44588.5Kwh - 43066.9Kwh / 28 Days = 54.342857Kwh/Day
Inverter B  57831.5Kwh - 56389.3Kwh / 28 Days = 51.507142Kwh/Day
Inverter C  49160.7Kwh - 47703.8Kwh / 28 Days = 52.032142Kwh/Day

05/02/16 - Check Up
Inverter A   49791.8Kwh - 43066.9Kwh /128 Days = 52.538281Kwh/Day
Inverter B   62694.0Kwh - 56389.3Kwh / 128 Days = 49.255468Kwh/Day
Inverter C   54064.1Kwh - 47703.8Kwh / 128 Days = 49.689843Kwh/Day

29/04/16 - Check up and Clean - Alpha coated 10Kw again - 2 Deg Pitch - Not Good!
Inverter A  53532 Kwh - 43088.6 Kwh / 180 Days = 58.02 Kwh/Day - $29.00/Day
Inverter B  66257 Kwh - 56410.8 Kwh / 180 Days = 54.70 Kwh/Day - $27.35/Day
Inverter C  57631 Kwh - 47725.5 Kwh / 180 Days = 55.03 Kwh/Day - $27.52/Day

Coated Section "A" Has Made an Extra $270 in the six months it has been Treated For!

After 6 Months my Aim was to Achieve at least 4.2Kw/Kw/Day - This is the CEC Average!

29/04/16 - Cleaned all Panels!
Inverter A - Producing 5.802Kwh/Kw/Day - 5.43339% Better than Inverter C (Reason is Pitch of Panels)
Inverter B - Producing 5.470Kwh/Kw/Day
Inverter C - Producing 5.503Kwh/Kw/Day

Wednesday, 27 April 2016

I happened to be on site for a Plumbing Job, and Walked Past this Inverter.

Results Calculated:

Labrador QLD 4215

5 Kw Inverter
16 x 250 watt Panels on Roof
19/04/16
Reading - Total 20983 KWh @ 15.21pm produced 6.259 Kwh for the Day?
http://pvwatts.nrel.gov/pvwatts.php
Site Calculation Estimate Allowing for Age = 22255 Kwh Total in Time.(allowing loss)

30660 Kwh Total Time is what you should have in my Calculation @ $0.50/Kwh
= $4838.50 Estimated Loss of Production by Not Maintaining!

How can I get the message to you all with Solar that you are Throwing away alot of Money?

These Results I post are collected Around the Gold Coast QLD

And are Actual Readings, not just Made up Information!
I Calculate my Results over at least 6 - 12 Months, Not from 8am to 12pm in the same day! (as other websites show!)

Tuesday, 26 April 2016

Update on Results From Today's 2Kw System Clean & Treatment

Ashmore QLD 4214
Facing - West
11 Panels
2 HWS

2 kW System
Installed - 25/02/2011
Inverter - Arora

First Clean - De-ionised Water
27/04/15
Reading - 11665 Kwh - 7.776Kwh / Day

27/04/16 - Yes - Alpha Eco Solar Treatment
Reading - 14419 kWh - 7.545 kWh/day = 23.7169%  Better than it should be Performing!
http://pvwatts.nrel.gov/pvwatts.php
2226Kwh/Year = 6.0986Kwh/Day


23.7169%  Better than it should be Performing! at this age!

Friday, 15 April 2016

Another Set of Results after a Visit for a Plumbing Job - Existing Customer

If you didn't already know, Solar Cleaner Australia & Wee Plumb are ME, so if you have a Plumbing Problem while I am on site Cleaning your Solar, I'll be happy to help :)

Solar Clean - 5 Kw System
Paradise Point QLD 4216
Age Estimated at 3 years 50 Days (Dated at 15/04/16)

22 Panels x 230 Watts = 5.060 KW
First Clean 02/11/15 - Yes - Unsure how old system would be as just bought place
Reading - 26232.08Kwh - Standard Clean


08/10/15
Reading - 25580.4Kwh

First Clean 02/11/15 - 24 Days - Alpha Eco Solar Treated
Reading - 26232.08Kwh - 27.15Kwh/Day

21/01/16 - 79 Days
Reading - 28338.86Kwh - 26.67Kwh/Day

15/04/16 - 84 Days
Reading - 30572.45Kwh - 26.59Kwh/Day

187 Days = 30572.45 - 25580.4 / 187 = 26.695Kwh/Day This is 27% Better than average!
Going Great Gary.

CEC Average for a 5Kw System in this Area is 21 Kwh / Day

This system is 3 Years & 50 Days Old (Estimated from calculations)

Average Production after this time frame allowing for deterioration is calculated to :
19.945205 Kwh / Day

This is 33.84169% Better :)

Thursday, 14 April 2016

I have just Found an Added Service for my Business to help my Customers even More!


http://www.facebook.com/HEAPSofNRG.

Heapsofenergy(ATF) pty Ltd

For STRESS Free Solar ; Measure Monitor Manage !
We provide Totally independent Specialist Monitoring advice that is NOT Product Solution Driven !

Is your Solar Investment's performance meeting the Optimum OR Original Sales / Installer Promises made ...? !


Our Algorithms are site specific BOM data sets that will identify what you should be getting on the P.V. Installation configuration . In addition this is a 100% Australian conceived and on shore partner driven Solar Solution set .

Register for our Complimentary S.H.C. Solar Health Check so you can get a Snapshot of your Systems Production from Day one . NB No site visit or Installer clambering all over your Roof space Either !

See www.heapsofenergy.solarlog-web.com.au/1418.html and we increased the Performance of the 5 Star Burleigh on View Bed & Breakfast @ Burleigh Heads by 350% ! after isolating the Installer Oversight :-) .

Money Back Guarantee ; If you have your system Cleaned by our Professional Contractors and have live monitoring installed ; We GUARANTEE the following

If our Live service Solution can't save you at least the initial investment made in 5 years you get the monitoring solution Free .

Looking forward to Helping you all even More with your Solar :)

Now not only Can I keep your Panels Clean and Treated to eliminate the 20% ($100-$1000 loss) each year!

And Also offer you an Electricity Retailer that gives you another $0,10 F.I.T on top of what you are getting.

But now we can Monitor your System to alert of anything that can be causing your system to under produce with this real time monitoring!

Monday, 11 April 2016

I though I would Share some Points From a Consumer Guide from the Clean Energy Council.

The Link is Below if you would like to Read the Whole thing.


http://www.solarchoice.net.au/blog/wp-content/uploads/Solar-Choice-Clean-Energy-Council-Solar-PV-Consumer-guide.pdf



A system manual that provides operation, maintenance and safety information should be provided by your installer. This must also include a system energy output (kWh) estimate.



 What angle should the solar panels be on?

 Solar PV panels produce most power when they are pointed directly at the sun. In Australia, solar modules should face north for optimum electricity production. The orientation of the panels will often have a greater effect on annual energy production than the angle they are tilted at. A minimum tilt of 10° is recommended to ensure self cleaning by rainfall. For grid-connected solar PV power systems, the solar panels should be positioned at the angle of latitude to maximise the amount of energy produced annually. Most Australian homes have a roof pitch of 20° to 30°. If your roof’s slope is not ideal, your accredited designer can create an appropriate mounting frame to correct the orientation and elevation of your panel. Failing this, the designer can advise you on the difference in energy output for different tilt and orientation.

Shading / Dirt Solar PV

panels should ideally be in full sun from at least 9am to 3pm. They should not be placed in shaded areas and be kept free from dust and dirt. Even a small amount of shade - from things like trees, roof ventilators or antennas - will have a large impact on the output of a panel, as it changes the flow of electricity through the panel. Shading or dirt on just one of the cells in a solar panel results in a loss of power from many cells, not just the one that is shaded.

Temperature

 The amount of electricity a solar PV panel can generate is reduced as temperatures increase. Solar panels operate best at ambient temperatures up to 25°C. However, if the ambient temperature is higher, the panel’s output declines.

 Warranties

 o What kinds of warranties come with the products? o Which warranties are your responsibility and which are the manufacturer's? o How long have the equipment manufacturers been in the PV industry? Long warranties are meaningless if the manufacturers aren't around in five years. o If you have to deal with the panel or inverter manufacturer in the future, do they have an Australian office?



Latest Reading and Results - 12/04/16

Parkwood QLD 4214

Installed Date - 03/05/15
1 year old
doing one string of 12 Panels Alpha Eco Solar

Ground Mounted System
5Kw Inveter, 6.240 KW of Panels

27/11/15 - Clean & Treatment on 12 Panels
Reading - 5867 KWH (204 Days = 28.76 KWH/DAY)

INSPECTION
11/01/16 - 45 DAYS
READING - 7051kwh (6812KWH?)
26.31kwh/day

INSPECTION
12/04/16 - 91 DAYS
READING - 9614 Kwh
28.16Kwh/Day

136 Days - 9614Kwh - 5867Kwh / 136 Days = 27.55 Kwh per Day Average
340 Days - 9614Kwh / 340 Days = 28.276Kwh per Day Average

Thursday, 24 March 2016

Results From Service Today @ Tamborine Mountain

Lots of Trees around, Gumtrees putting alot of Sap on the Panels!


Lowset Metal Roof -

Rebate - $0.04/Kw? ( Advised about Extra $0.10 on Top of Current FIT)
Inverter - 5 KW
Facing - 12 Panels WEST, 8 Panels NORTH (20 x 25 watt Panels)

First Clean
25/09/15
Reading - 5098Kwh - 12.7Kwh/Day
Aim for 15.24Kwh/Day(20% improvement)

6 Monthly Clean ( Terri Text to Get Clean, Booked for 25/03/16)
Six Monthly Price = 20 x $6 = $120 Bartercard - to book every 6mths
25/03/16 - 180 Days
Reading - 8021kwh
Average = 8021 - 5098 / 180 = 16.2388Kwh/Day ( 27.86% Improvement)

Better than I Guaranteed!!!











Wednesday, 23 March 2016

Great news Yesterday - Again!

Was told that a Customer of one of my Cleans/Treatments who was getting approx $30 Rebate on their quarterly electricity bills.

Just recently after the Treatment of their Panels got a $300 Rebate on their electricity bill

Asked this morning for an official review, will add to this once i get it.

Great News though, not that I didn't expect it, getting great news off all my customers slowly :)

Tuesday, 22 March 2016

Alpha Eco Self-Cleaning Solar Panel Treatment is a nanotechnology-based application that protects glass surfaces from being tarnished and helps prevent the accumulation of dirt and other contaminants.

The applied sealant forms an invisible film on the surface that, when triggered by sunlight / UV rays in what is called a photocatalytic process, breaks down “muck” and dirt to the point that they are easily carried away by rain or water.

The compounds in Alpha Eco Self-Cleaning Solar Panel Treatment have powerful hydrophilic properties, meaning they attract water and push other substances – such as bird droppings, dirt and other organic pollutants – aside, subsequently forming a self-cleaning membrane that keeps surfaces clean and functioning longer. (Self-cleaning effects are obtained after 15 - 24 Hours and last up to 3 years.)

The treatment is perfect for Windows, Solar Panels, Skylight windows, Mirrors, Shower Screens etc...



Thursday, 10 March 2016

So what did I find out this week? mmmmmmmmmmm


Well again I found another Solar Owner that did not know their Panels needed Cleaning?


What is happening, it is on Adverts on the TV? Does no one take notice any more?


I am only trying to help out those with Solar Panels to make more money!


I worked out this week that with my #cleanswitch&save deal you, the customer only pays 1.5% of what you are guaranteed to make over the 3 year Program.


1.5%, that's $1.50 to make your self $100 in Electricity savings?


Any way, My Partner keeps telling me that I calculated things out more than others.

 I guess I do, but how else would you know if you are getting enough return on the money you are investing into your Solar?


Any way have a great weekend all, and if you are interested in finding out more about my new #cleanswitch&save deal then don't wait too long, call me or email me or Text me to book in an appointment to sit down and go through it to see how much "Extra" saving you are going to produce from your Solar!!



Tuesday, 8 March 2016

Latest Results Obtained

Solar Program Offer for Complex - Alpha Eco Solar Application

William and Audie Burns

Hope Island QLD 4212

14 PV Panels = 3Kw + 2 Solar Hot Water Panels
Facing - SOUTH

20/08/2015
Reading - 16665Kwh ( Solarhart Panels and Inverter)

09/09/2015 -
Reading = 16788Kwh
= 6.15Kwh/Day over last 20 Days

12/01/16 (132 Days from First Records)
Reading = 18636Kwh
= 18636Kwh - 16665Kwh = 1971Kwh/132Days
= 14.9318Kwh/Day

This is Awsome!! :)

over 142% improvement

Money well invested I would have to say?

I am getting some great information this week.

I was just informed by one of my Bidet Customers today in Tweed Heads
That he has a guy that cleans his Panels (2Kw System) for $25 every year

I asked him could i have a look at his latest bill to see how much the $25 clean was improving his Solar ?

Bill was from Origin Energy

Dec till Feb 2016

Solar Generated was 632 kwh over 90 Days = 7.02 Kwh / Day

CEC Average is for a 2 Kw System - 8.4 KWH / Day

This guy is on $0.60 Rebate

All of my Customers Generate at minimum CEC Average!!

This guy has missed out on $74.52 extra worth of saving just from his last bill!!!

So for paying a guy to clean his Panels $25, he has not gained anything! he is not even getting his average!! over summer!!!

I ask you?

Is it worth the $25 he paid to get nothing (actually he got a negative!)


He should have given his $25 to a charity?




Monday, 7 March 2016

Some very interesting information i received from one of my customers today.


Another Solar Cleaning Business - Lime Solar Cleaning

Advertised on the TV $89 to clean your Panels! (= Average of $38.14 per Panel, Based on 14 Panels)
He advised me this price includes:
- Any Domestic Clean
- Every 6 Months is Recommended
- They use De-ionised Water
- They Clean your Panels from the Ground
- Use a soft Broom and Pole

Solar Cleaner Australia Clean: Alpha Eco Solar Program @ $35 per Panel

ALPHA ECO SOLAR CLEAN PROGRAM CONSISTS OF:

OUR UNIQUE 3 STAGE CLEAN AND PROTECTION PROCESS

STAGE 1 - DE-IONISED WATER CLEAN WITH A SOFT BRISTLE BRUSH

STAGE 2 - NORWEX TILE/GLASS CLEAN

STAGE 3 - ALPHA ECO SOLAR / ZERO VOC CLEAN AND PROTE


WHAT WE CHECK ON YOUR SYSTEM - (You could not do this from the Ground!!!)

CLEANLINESS – CHECK AROUND MODULES                                                                                               
ALL LABELS IN PLACE                                                                                                                                               
CHECK PANELS FOR 

FRACTURES                                                                                                                        

MOISTURE PENETRATION                                                                                                               

FRAME CORROSION                                                                                                                           

VISUALLY CHECK FOR HOT SPOTS ON ISOLATORS                                                        

ENSURE INVERTER IS CLEAN AND ENSURE AIR FLOW                                                  

CHECK ALL MECHANICAL FIXINGS                                                                                           

CHECK LAMINATION OF BEHIND PANELS                                                                            

CHECK FOR SHADING OVER PANELS AND CELLS                                                           



Guess I will leave it up to you, who you would rather Pay your hard earned Money too.




D PANELS                                                                            CHECK FOR SHADING OVER PANELS AND CELLS                                                           


Thursday, 3 March 2016

Hi All

Still people out there confused as to why to chose my Alpha Eco Solar Cleaning Program.

So I tried to explain the Price Differences on my Website this week.

Cost Differences of Cleaning Choices - Example of 5 KW System with 24 Panels (Lowset)

12 Monthly Clean (if your Panels have not been cleaned for at least 12 Months)

 - 24 Panels x $9 per Panel = $216 (Results show Increase of 5-10% Better)

6 Monthly Clean (Once your Panels are Cleaned you can chose 6 Monthly Cleans)

 - 24 Panels x $6 per Panel = $144 (Results show increase of 15-28% Better)

Over a 3 year time frame this would cost you $936

Alpha Eco Solar Program (Zero Voc Clean) Cleans and Protects your Panels for 3 years!
 - 24 Panels x $35 per Panel = $840 (Saving of $96)
 - Results show increase of 15-35% Better


Also Still getting the Forms and confirmation through for the Extra $0.10 on top of your current Rebate, so be patient please it wont be long, but still click the link on my website, and some one will contact you as soon as it is all sorted!!

So as I have mentioned before

With the Extra $0.10 Rebate on top of what you are already getting, be it $0.06, $0.08, or $0.44
and with my Alpha Eco Solar Cleaning Program

You will be effectively gaining between 40 - 80% increase on your Solars Performance!

For those thinking money terms

For $35 per Panel, you will be nearly doubling your Savings on your electricity bill, against Thousands of Dollars on either more Panels, or Battery Back up.

My Estimate is for every $1 you invest i can get you a return of $1.80 - Not sure if you can find anything else that will get you those sort of returns?

If you can let me know :)

Have a great weekend!!