RESULTS


Nerang QLD 4211
2.8Kw System
Inverter - 2.8Kw
CEC Average = 11.76Kwh/Kw/Day
Age Estimated - April 2010 Installed?

18 Panels x $9ea = 12 Monthly
18 Panels x $6ea = 6 monthly
18 Panels x $35ea = 3 yearly with Annual Inspection
Reading 16/05/2015- 20454KW

12 Monthly Clean - Alpha Eco Solar Applied
18/05/16 - 367 Days
Reading - 23829 Kwh - 9.196185 Kwh/Day
http://pvwatts.nrel.gov/pvwatts.php = Average 8.4123285Kwh/Day
9.318% Better than it should be

Friday, 13 May 2016

Mount Nathan Winery - Clean & Treatment
System Size - 22 x 230watt Panels = 5.060 Kw
Panel Size - 230 watts
Invetre Brand - Sunteams
Inveter Size - 5 Kw
Age - Approx 5 Years
Facing - W /S-W


18/04/16
Reading - 26375 Kwh - Average Approx 14.45 Kwh / Day (Average CEC 21 Kwh / Day



13/05/16 - 25 Days
Reading - 26642kwh - 10.68 Kwh / Day

Lets get this Puppy Producing :)

Wednesday, 11 May 2016


Hi All

Results From Yesterday Mornings Clean.
This Customer Requested a Standard Clean 12 Monthly @ $9 Per Panel
I did explain that 12 Monthly Clean do not Produce much results if Any, This is Also found on my Website. So we can see That This Customers Solars Performance is Dropping Steady by around 2.2-3% each Year, Not the Estimated 15-20% loss per Year. (or should I say 35-40% That some Cleaner Claim!)
So myself here at Solar Cleaner Australia, Not Happy with these Results for my Customer, Have Decided to Put him on the Alpha Eco Solar Treatment Program. Aiming to get to at least what the CEC tell us is the Average for our Area, of 9.24Kwh/Day
Challange is "ON" :)



12 Monthly Clean Program, Standard Clean Only.
Mudgeeraba QLD
Installed Approx 2010
Size : 2.2 Kw
FIT - $0.44
Lowset Tiled Roof
12 Panels x $9 = $108 / Year
Readings
10 /05/2014 - 11429 Kw - 7.93Kwh/Day - Estimated

11/05/2015 -  14253 Kw - 7.74Kwh/Day (CEC Average = 9.24 kwh/Day for a 2.2 kW Systems)

Alpha Eco Solar Program Started!
11/05/16
Reading - 17013 kWh - 7.56 kWh/day

http://pvwatts.nrel.gov/pvwatts.php = 2391 Kwh / Year = 6.55Kwh/Day this allows age loss
We are getting at least 15.4% better than estimated amount due to age! this is good!

12 Month Check Up - Aiming for min 9.24 Kwh/Day
11/05/17

Monday, 9 May 2016

Solarclean - 5Kw System - Nerang QLD - Media Solutions
Installed April 2012

First clean - Standard De-Ionized Water
22/04/14
Reading - 14576Kwh - 20.23Kwh/Day

Second clean - 181.5 Days - Standard De-Ionized Water
21/10/14
Reading - 18231Kwh - 20.1377 Kwh / Day

Third Clean - Start Alpha Eco Solar Program - 199.5 Days
08/05/15
Reading - 22888Kwh - 23.3434 Kwh / Day ( average = 21Kwh/Day)

06/11/15 - 180.5 Days
Reading - 26547Kwh - 20.27 Kwh/ Day

09/05/16 - 182.5 Days - 12 months with Alpha Eco Solar Program
Reading - 30894 Kwh - 23.88 kWh/day


De-Ionized Water                                       Alpha Eco Solar Program            
21/10/14 - 20.1377 Kwh/Day                    06/11/15 - 20.27 Kwh/Day

08/05/15 - 23.3434 Kwh/Day                    09/05/16 - 23.88 Kwh/Day


Over the last 12 Months with the Alpha Eco Solar Program this System has produced 8006 Kwh

In Comparison to if they were not Cleaning Panels at all! 5624 Kwh per year!

42% Better - And I have been told so much over the Last 5 Years "Solar Companies Say that your Panels Don't Need Cleaning"